Hydraulic Industry

Case  Introduction
DOCO Oil Chiller applied to hydraulic industry for customer Taitian Hydraulic
 
 Technical Parameters 
 
MODEL ITEM Model DC- YL28P DC- YL35P DC- YL55P DC- YL83P DC- YL135P DC- YL210P-D DC- YL270P-D DC- YL405P-T DC- YL540P-F
HorsePower HP 1 1.5 2 3 5 8 10 15 20
Cooling Capacity kcal/h 2390 3061 4730 7086 11610 18060 23220 35260 46440
Cooling Capacity KW 2.78 3.56 5.5 8.24 13.5 21 27 41 54
Total Input Power KW 1.7 2.1 2.6 4.2 6.5 12.1 14.1 20.5 24.8
 Compressor Power KW 0.8 1.2 1.6 2.5 4 3*2 4*2 4*3 4*4
Temperature Range 10-50℃,Desired Temperature of Hydraulic Oil:30-40℃
Power Supply Power 380V/50Hz
Oil Pump Flow L/min 20 25 25 32 50 80 100 150 200
Inlet/Outlet Pipe
Caliber
Inch 1/2 1/2 3/4 1 1 1/2 1 1/2 2 2-1/2 2-1/2
Refrigerant   R22 ( Optional Environmental Refrigerant R407、R410)
Condenser   Air cooled condenser(copper tubing and corrugated aluminum fin, to improve the cooling efficiency20% )
Evaporator   Stainless steel 316 plate heat exchanger/ shell and tuge exchanger
Fan   Large-flow and Low-Noise Axial Fan Motor
Dimensions Length 585 605 605 685 886 1206 1306 1606 1806
Wi mm m
dth m
525 535 555 685 766 656 656 956 1106
Height
mm
962 962 1080 1142 1350 1550 1650 1860 2080
Safety protection Delayed,over current,compressor over temperature,high and low pressure,over flow switch, phase
sequence,phase-missing,exhaust overheating,antifreezing.


 Technical Specifications: 
 
1. Model number specification:e.g. HN-YL210P-D, “HN” indicates company code, “YL” indicates oil chiller, “210” indicates refrigerating capacity 210KW, “P” indicates built-in pump, “D” indicates dual system ( two compressors), “T” indicates three compressors, “F” indicates four compressors.
2. * Compressor Power: *2 indicates two compressors working and two separate cooling system.
3. Nominal cooling capacity calculated according to:Ambient temperature: 35℃. Oil inlet flow temperature: 35℃. Oil outlet flow temperature: 30℃. Oils: ISO Vg46.
4. The oil suction inlet must be connected with rigid tube, and it's necessary to install filter. Meanwhile, it's prohibited to install valve on the oil outlet.
5. The length of oil suction tube should not be more than 1.5meters; Otherwise, the diameter of oil suction inlet must be increased.
6. Working range: Oil temperature ranges from 15℃ to 50℃. Temperature difference between inlet and outlet oil is from 3℃ to 8℃. It is better to run the oil chiller while the ambient temperature at or below 42℃; Otherwise it's necessary to use high temperature models.
7. We reserve the right to revise the above information without prior notice. 